Power Generation Vehicle Load Testing Equipment
Market price:
Keywords:
Power Generation Vehicle Load Testing Equipment
Product Description
Features and Benefits
1. The device is equipped with a precision R‑type load, which comprises a continuously adjustable resistor array, an electrical parameter testing system, an automatic control system, and a software analysis system.
2. Each device is equipped with an intelligent load control board that, in response to commands from the host system, can activate the various power modules of each phase.
3. The device features built-in multi-channel electrical data acquisition, enabling precise measurement of electrical parameters such as voltage, current, active power, and reactive power for each of the three phases.
4. The equipment features independently adjustable three-phase outputs, enabling simulation of the operating conditions under unbalanced loading for the device under test.
5. The built-in load has a minimum rated power of 1 kW, with a step size of 1 kW, and its power is continuously adjustable.
6. The power factor of the resistive load is ≥0.99;
7. The host is controlled by electronic circuitry and features automatic over‑temperature alarm and protection: in the event of overheating or overcurrent due to special circumstances, it can automatically disconnect the load.
8. The equipment can simulate the generator’s load‑testing requirements across the 25%, 50%, 75%, 85%, 100%, and 110% load ranges.
9. The analysis software can generate load‑versus‑time curves and offers 120 predefined loading modes. Based on the preconfigured settings, the system automatically performs loading or unloading tests, and upon completion of the selected mode, it automatically returns to a fully unloaded state.
Technical Specifications
| Parameter Item | Parameter value |
|---|---|
| Device Name | Generator Set Load Test Equipment (Programmable AC Load) ACLT-38100T |
| System Architecture | The main circuit comprises a resistive load, a resistor switching switch, a cooling fan, parameter acquisition equipment, loading control software, and the chassis assembly, among other components. |
| Resistive load power R | 1050 kW: ① Phase‑by‑phase independent control for A, B, and C: 1–10 kW, 20 kW, 30 kW, 40 kW (with each phase—A, B, and C—capable of 100 kW), totaling 300 kW across the three phases; ② Simultaneous three‑phase control: 50 kW, 100 kW, 200 kW, 300 kW, for a combined total of 750 kW. |
| Phase-separated independent control function | Phases A, B, and C can each be controlled independently. |
| Step size | 1kW |
| Access load voltage | Three-phase AC 400 V/50 Hz or single-phase AC 230 V/50 Hz |
| Phase voltage measurement range | 0–300 V; accuracy ±0.2%; resolution 0.1 V |
| Current measurement range | 0–2000 A; accuracy ±0.5%; resolution 0.1 A |
| Frequency measurement range | 45 Hz–65 Hz; resolution 0.1 Hz |
| Power measurement accuracy | Accuracy: ±0.5%; Resolution: 0.1 kW |
| Wiring method | Three-phase four-wire system or single-phase two-wire system |
| Communication port | RS-485 interface (supports remote communication) |
| Control method | Automatic control and automatic loading are achieved via a remote PC, with the load’s discharge current continuously adjustable. |
| Storage device | Measurement data is directly imported into a PC, and the analysis software features automatic recording and automatic storage capabilities. |
| Cooling method | Fan-forced air cooling |
| Applicable ambient temperature range | -10~+40℃ |
| Power supply | AC 220V/50Hz |
| Maximum device power | Less than 50 million |
| Dimensions (mm) L×W×H | 1700×2400×2200 mm, 1 cabinet, approximately 1500 kg |
Online Inquiry