High-Power Intelligent Load Bank
Market price:
Keywords:
High-Power Intelligent Load Bank
Product Description
I. Overview of High-Power Intelligent Load Banks
With the development of China’s economy, the load capacity of electrical equipment continues to grow, necessitating a corresponding increase in the capacity of generator sets used as backup power sources. To meet this demand, multiple high‑power diesel generators must be interconnected. Taking into account transmission losses and construction challenges associated with large‑capacity power delivery, as well as the need to accommodate high‑voltage electrical equipment, the use of high‑voltage generator sets has become a preferred solution for many users.
The high‑voltage generator set delivers a 10 kV output, matching the voltage of the existing power supply system, allowing direct connection and eliminating the need for costly investments in high‑current cables and other power distribution equipment. Moreover, at the same power rating, the higher output voltage results in lower output current, minimizing power losses during transmission and making it well suited for long‑distance delivery. Particularly in applications with heavy load demands and extended transmission distances, high‑voltage diesel generator sets offer distinct advantages—such as large‑capacity, long‑distance power supply, robust reliability, and reduced costs for associated distribution systems. Consequently, these units are now widely deployed in industries and mining operations, by telecommunications providers, data centers, ports, metallurgical facilities, airports, and other sectors.
High‑voltage generator sets offer certain advantages, but compared with low‑voltage diesel generators, they represent a substantial capital investment. When comparing domestic and international high‑voltage diesel generator sets, domestically produced models enjoy a clear price advantage and have, in terms of technology, largely met the needs of most Chinese enterprises. Consequently, from a cost‑effectiveness standpoint, an increasing number of companies are opting for locally manufactured high‑voltage diesel generator sets. Although domestic high‑voltage diesel generators continue to make technological advances, they still lag behind their foreign counterparts. Certain critical components can be prone to failure if the entire unit is not properly maintained, which may compromise performance during critical moments and drive up maintenance costs. Therefore, it is essential to conduct regular load‑testing and routine maintenance on the engine.
The high‑power intelligent load bank can accurately measure the output power and load‑carrying capability of high‑voltage generator sets. Comprising a measurement‑control module and a high‑voltage load bank, it can be integrated with a computer to enable intelligent operation, automatically performing specialized tests on all electrical parameters of the generator set while generating charts, curves, and test reports. This provides a scientifically sound testing methodology and reliable data for high‑power generator equipment.
High‑voltage load bank + electrical parameter acquisition instrument + intelligent control software = high‑power intelligent load bank
II. Functions of the High-Power Intelligent Load Bank
1. Measurement parameters: basic functions including the generator’s steady-state three-phase voltage, current, active power, reactive power, apparent power, power factor, active energy, reactive energy, frequency, and operating time.
2. Harmonic Analysis: Total voltage harmonic (total harmonic distortion), total current harmonic (harmonic content from the 2nd to the 50th order, as well as the total harmonic content);
3. Dynamic Testing: Includes engine ripple testing, step‑up/step‑down testing, and setpoint adjustment testing. It can automatically measure the maximum and minimum values of voltage, current, and frequency during sudden load changes, as well as the recovery time, and displays the corresponding step‑up, step‑down, voltage, current, and frequency waveforms.
4. Automatic Testing: The intelligent control software features built-in test procedures, allowing users to pre‑set load levels ranging from 0% to 25% to 50% to 75% to 100%, as well as up to 110%, along with corresponding run times, step‑load application, step‑load removal, power fluctuation, and setting‑point testing, thereby enabling automated testing.
5. Testing Software:
1) Display modes: digital display, analog dial display, and automatic test result display; users can select any of these three modes. The display accuracy is Class 0.5, ensuring accurate representation of values across all voltage ranges and power levels.
2) It can display real-time and historical data, and supports printing voltage, current, frequency, and power curves; voltage waveform; current waveform; power waveform; frequency waveform; power factor waveform; step‑up voltage waveform; step‑up current waveform; step‑up frequency waveform; step‑down voltage waveform; step‑down current waveform; step‑down frequency waveform; total voltage harmonic waveform; voltage harmonic bar chart; current harmonic waveform; current harmonic bar chart; and harmonic waveforms.
3) Displayable and printable reports: steady-state performance test report, transient test report, and test data report.
4) Data Management: Test reports can be searched, displayed, and printed based on criteria such as date, model, and machine number.
6. Control Mode: Local control, remote computer control.
Local Control: The load bank features a built-in control panel with stepped control.
Remote Control: The remote computer performs all functional tests on the high‑voltage diesel generator test platform, records the relevant parameters, and generates reports. It supports exporting data in Excel and Word formats for convenient access at any time.
7. Loading modes: manual loading, automatic program-controlled loading, and sudden unloading.
8. Emergency Interruption: The experimental procedure is equipped with an emergency interruption function that, during an interruption, disconnects all loads. Upon completion of troubleshooting, the system can automatically and incrementally restore the load conditions to their state prior to the interruption, allowing the experiment to resume, or revert to the initial state of the experiment for re‑execution.
9. Protection Functions:
1) Equipped with rainproof and lightning-proof features, it enables all-weather testing under load.
2) All load‑adding and load‑removing operations are equipped with safeguards to prevent operator errors.
3) The load is equipped with multiple protection functions, including emergency stop, overvoltage protection, short-circuit protection, temperature protection, smoke detection, fan interlock protection, fan airflow protection, fan overload protection, and automatic phase-sequence switching protection.
10. Load Expansion Capability: Allows parallel connection of load banks within the same series to increase capacity, while maintaining the aforementioned single‑unit and multi‑unit load testing functions.
11. This testing platform supports both hardware and software upgrades.
III. High-Power Intelligent Load Bank Products
Customized AC loads tailored to user requirements. Ranging from 0 to 5,000 kW, available in single-phase configurations at 200 V, 380 V, 400 kV, 6.6 kV, 10 kV, and 12.5 kV.
AC400-250kW: Load Test Bank for Nuclear Power Generator Sets
ACLT-38100: Discharge power adjustable from 1 to 1000 kW
ACLT-38150: 1500 kVA Generator Set Load Test
ACLT-38200: Discharge power adjustable from 1 to 2000 kW
ACLT-38300: Discharge power continuously adjustable from 1 to 3,000 kW.
ACLT-38500H: High-Power Grid-Connected Inverter Certification and Testing Device
We offer custom solutions for high‑power, high‑voltage load banks. For more details, please contact Qunling Energy.
IV. Features of High-Power Intelligent Load Banks
1. It can measure the generator’s steady-state three-phase voltage, current, active power, frequency, operating time, and other basic parameters; reactive power, apparent power, power factor, and other parameters are provided as optional functions.
2. Equipped with harmonic analysis functionality, it can simultaneously measure the 2nd to 50th harmonic components and the total harmonic distortion of both voltage and current; it also features energy accumulation.
3. Transient testing (sudden load application and removal) function: automatically measures the maximum and minimum values of voltage, current, and frequency during abrupt load changes, as well as the recovery time.
4. Equipped with robust voltage waveform recording capabilities and featuring opto-isolated RS485/RS232 serial communication, the device offers highly versatile serial-port functionality.
5. It can not only retrieve all steady-state parameters, but also acquire transient response data for step‑up and step‑down events, as well as voltage, current, and frequency waveforms, along with voltage and current harmonic waveforms and their respective harmonic content.
6. When used in conjunction with a host computer, it can automatically measure all electrical parameters of the generator. It generates various charts, curves, and test reports automatically, ensuring standardized operation and high reliability. The data is comprehensive, the reports are highly versatile, and users can add signatures or modify the format as needed.
7. The total load control function enables abrupt load application and removal (this function is not available on water loads).
8. Remote control functionality: manual loading and unloading can be performed via a remote controller.
9. Equipped with the capability to collect water‑load data and featuring provisioned terminals for current transformer wiring.
10. The ramp-up and ramp-down functions are automatically controlled by the computer, while power settings are manually adjusted on the panel or controller.
11. Equipped with temperature detection and protection, as well as fan failure detection and protection functions.
12. 100–2000 kW, with manual or automatic adjustment as desired; the load can be gradually increased or decreased, or subjected to sudden changes.
13. It achieves intelligent control and can automatically test various parameters of generator sets, including dynamic parameters, providing a scientific testing method for high‑power generator sets.
V. Manufacturing Standards for High-Voltage Diesel Generator Set Testing Platforms
GB/T 2820.5-2009 “Reciprocating Internal Combustion Engine–Driven Alternating Current Generating Sets – Part 5: Generating Sets”
GB/T 13032-2010 “General Technical Specifications for Marine Diesel Generator Sets”
GB/T 6994 "Electrical Equipment for Ships"
GB/T 1029-2005 “Test Methods for Three-Phase Synchronous Motors”
GB 14711-2006 “Safety Requirements for Small and Medium-Sized Rotating Electrical Machines”
GJB 2815-97 “General Specification for Load Testing of Internal Combustion Engines”
GJB 235-87 “General Technical Requirements for Industrial and Medium-Frequency Mobile Loads”
GJB 1488-93 “General Test Method for Load Testing of Internal Combustion Engines”
JB/T 10303-2001 “Technical Specifications for Power-Frequency Diesel Generator Sets”
EN 60204-1:2006 “Safety of Machinery — Electrical Equipment of Machines”
GB/T 11022-1999 “Common Technical Requirements for High-Voltage Switchgear and Control Equipment Standards”
GB 3804-1990 “AC High-Voltage Load Switches for 3–63 kV”
GB 3309-1989 “Mechanical Tests of High-Voltage Switchgear at Ambient Temperature”
VI. Application Cases
The ACLT-38200 intelligent load bank (10.5 kV, 2000 kW) was designed and manufactured by our company for Dr. Peng Telecom Group as a load‑testing device for data‑center generator sets. It has now been delivered to data centers across major provinces and municipalities nationwide, where it has successfully passed acceptance testing and been put into service.
For additional test solutions—including load banks, load cabinets, dry-type loads, AC test load banks, high‑power AC load cabinets, and generator test load banks—please contact Beijing Qunling.
Online Inquiry