Power Grid Adaptability Test Facility
Market price:
Keywords:
Power Grid Adaptability Test Facility
Category:
Product Description
Grid simulation power supplies are suitable for wind and solar power generation. and new energy sources such as energy storage power stations source Power station Grid-connection function test, Meeting the most standard requirements It offers standard testing functions such as grid adaptability and fault ride-through, and also supports weak grid simulation, wideband frequency sweep, impedance analysis, and anti-islanding detection. Inertia response, Advanced testing functions such as damping control and active load simulation provide robust support for grid-connection testing and analysis of new energy systems.
Technical Features
1. Safe and reliable
Shock-absorbing design, ideal for long-distance transport;
With a bypass, pausing the test does not affect unit operation.
2. Flexible application
Containerized structure, facilitating frequent lifting and transportation;
Supports parallel operation of multiple units to meet diverse power testing requirements.
3. Detection Support
It has low output impedance and fast output short-circuit current limiting.
Comprehensively covers grid-connection and grid-forming test scenarios for large-capacity new energy systems, including wind, solar, energy storage, and hydrogen.
Software upgrades can be performed in accordance with standard updates.
4. Human-friendly
It features remote operation, a comprehensive software interface that is both simple and easy to understand.
It provides a highly standardized test output process and features customizable online waveform programming.
Upgraded in accordance with the latest standards to meet the most recent testing requirements for wind, solar, and energy storage systems.
System Functions
Name
|
Function Description
|
Voltage regulation
|
1) Capable of providing a stable, adjustable voltage output;
2) Possesses standard voltage deviation adaptability and one-key output testing capability.
3) Possesses standard overvoltage adaptability and one-key output testing capability;
4) The voltage output range is customizable.
|
Frequency Regulation
|
1) Capable of providing a steady-state adjustable-frequency output;
2) Possesses standard frequency deviation adaptability and one-key output test capability;
3) Possesses standard one-button output testing capability for over/under frequency adaptation;
4) Possesses standard one-step output testing capability for primary frequency regulation ;
5) Possesses standard one-click output testing capability for inertia response ;
6) The frequency output range is customizable.
|
Three-phase output voltage imbalance
|
1) Supports two setting modes: voltage unbalance degree and independent three-phase voltage settings;
2) Possesses standard three-phase voltage unbalance adaptability and one-key output testing capability.
|
Output voltage flicker
|
1) Supports two setting modes: short-term flicker Pst and voltage fluctuation magnitude;
2) Possesses standard flicker-adaptive one-click output testing capability
|
Harmonic output capability
|
1) Supports arbitrary harmonic combination outputs from the 2nd to the 50th order;
2) High-precision harmonic output can be achieved under both no-load and loaded conditions;
3) Harmonic output capability is customizable
|
Interharmonic output capability
|
1) Supports single interharmonic output and simultaneous output of two interharmonics;
2) Interharmonic output capability is customizable
|
Fault Ride-Through Voltage
|
1) Capable of conducting high-voltage ride-through, low-voltage ride-through, and zero-voltage ride-through tests;
2) Supports three modes: single-phase voltage fault, two-phase voltage fault, and three-phase voltage fault;
3) Supports configuring the number of fault occurrences;
4) Supports fault ride-through at a specified angle;
5) Supports voltage phase step during fault ride-through and when voltage is restored;
6) Fault ride-through voltage capability is customizable
|
Phase Step
|
Supports two modes: phase jump triggered at a specified angle, and phase jump triggered at a random angle.
|
Power Grid Impedance Simulation
|
1) It features two modes: virtual impedance simulation and short-circuit ratio simulation.
2) In the power grid Impedance During the mock test Can be performed Testing of other power grid simulation functions
|
Impedance Scanning
|
1) Supports three sweep modes: positive-sequence, negative-sequence, and combined positive/negative-sequence;
2) The frequency sweep consists of three stages, each of which can be individually configured with start/end frequencies, voltage amplitude, disturbance frequency step size, and duration.
3) After the frequency sweep is completed, a single click generates the disturbance voltage spectrum analysis and the impedance characteristic analysis results of the device under test. ;
4) The disturbance voltage frequency range is customizable.
|
Anti-islanding detection
|
1) Supports three modes: automatic islanding detection, power setting, and RLC setting;
2) The quality factor can be displayed in real time;
3) can Automatically calculate the recommended RLC values based on the current power.
|
Custom Output Waveform
|
1) Capable of outputting custom curves for voltage, frequency, and harmonics;
2) Supports online import and export of waveform editing data files.
|
System Functions
The output side complies with energy storage testing standards and specifications such as GB/T 34133 and CQCPV15001. The specific performance indicators are as follows:
1) Output steady-state voltage with an adjustment range of 80% to 130%, a minimum step size no greater than 0.01%, and an output deviation no greater than ±0.2%; under no-load conditions, the total harmonic distortion of the voltage shall not exceed 0.5%.
2) The output frequency adjustment range shall be 45–66 Hz, with a minimum frequency step size of 0.01 Hz and an output frequency deviation of ≤ ±0.01 Hz.
3) Output voltage unbalance test: supports adjustable three-phase voltage unbalance levels from 1% to 15%, with a minimum adjustment step of 0.1% and a deviation of ≤±0.2%. It supports two setting modes: unbalance level setting and voltage magnitude/phase setting.
4) Output voltage flicker testing, supporting user-defined Pst values from 1 to 10, with a minimum adjustment step of 0.01; output flicker deviation ≤ ±0.1; and two setting modes: Pst configuration and voltage fluctuation value configuration.
5) Output voltage harmonic testing meets a deviation of ≤±0.3%; harmonic output capability is 6% for single harmonics from the 2nd to the 25th, 3% for the 26th to 43rd, and 2% for the 44th to 50th; combined harmonics are supported with THD ≤10%, with no limit on the number of combinations, and simultaneous multi‑harmonic output is supported. Harmonic testing between 5 and 100 Hz is also supported, with a deviation of ≤±0.05%.
6) Primary frequency regulation capability test: meets a frequency range of 45–66 Hz, with a step size of 0.01 Hz and a deviation ≤ ±0.01 Hz; the rate of frequency change is continuously adjustable, and it supports frequency step tests ranging from 0 to ±5 Hz.
7) Inertia response capability test, adjustable from 0.1 Hz/s to 50 Hz/s.
8) High-voltage ride-through testing function, supporting three-phase, two-phase, and single-phase high-voltage fault ride-through; output voltage range: 110%–140%; no-load output tolerance ≤ ±3%; step time adjustable from 5 ms to 10 s; supports trigger angle setting from 0° to 360°; supports phase shift setting from 0° to 90°.
9) Low-voltage/zero-voltage ride-through testing function, supporting low/zero-voltage fault rides through in three-phase, two-phase, and single-phase modes; transient output voltage adjustable from 0% to 90%; no-load output allowable deviation ≤ ±3%; step time programmable from 5 ms to 10 s; supports trigger angle setting from 0° to 360°; supports phase shift setting from 0° to 90°.
10) Supports continuous fault ride-through testing, meeting test requirements for low-to-high, high-to-low, and continuous low-voltage ride-through scenarios. Step time is user-configurable from 5 ms to 10 s, and the number of fault ride-through cycles is no fewer than 9.
11) It features virtual impedance-based weak grid simulation, supporting settings for short-circuit ratio and reactance-to-resistance ratio, as well as three modes for resistor, inductor, and capacitor values. The short-circuit ratio is adjustable from 0.8 to 100.
12) Features a wideband impedance scanning capability from 1 to 1250 Hz, supporting independent or combined positive- and negative-sequence frequency sweeps, as well as segmented parameter configuration; also supports plotting wideband positive- and negative-sequence impedance curves.
13) Features phase-angle step testing; the phase-angle step can be set from -90° to +90°, with a phase-change time ranging from 5 ms to 10 s.
14) Features islanding simulation, supporting three modes: automatic islanding acquisition, power setting, and RLC setting; can display the quality factor in real time; and can automatically calculate recommended RLC values based on the current power.
15) Supports multiple test modes and testing of grid-forming renewable energy generation equipment.
16) Damping Control: Supports simulation of grid oscillations in the 0.1–100 Hz range, with a choice of sine or square wave excitation.