CPMT-1800 DC Charging Pile Electrical Energy Metering Verification Device
Market price:
Keywords:
CPMT-1800 DC Charging Pile Electrical Energy Metering Verification Device
Product Description
Testing of DC charging piles compliant with the Chaoji and 2015+ (2015) communication standards;
Equipped with a 600A national standard 2015+ charging gun socket (compatible with 2015) and a 600A Chaoji charging gun connector, it meets the requirements specified in GB/T 20234.3‑2023 and GB/T 20234.4‑2023.
The DC power module can be calibrated and traced using both the pulse method and the standard meter method.
Equipped with external acquisition interfaces such as DC, DC‑, CC1, CC2, A+, A‑, and PE;
Built-in vehicle BMS simulation unit, capable of interfacing with charging stations compliant with the Chaoji and 2015+ (compatible with 2015) standards, enabling charge initiation and the configuration of charging voltage and current.
Meets the verification requirements specified in JJG 1149‑2022 and can generate reports.
Built-in 0–1500 V battery voltage simulator, capable of simulating vehicle battery voltages according to test requirements;
Built-in GPS/BDS clock acquisition module, enabling clock error testing for charging piles.
It features a built-in module for acquiring ambient temperature, humidity, and atmospheric pressure, enabling on-site measurement and verification of environmental parameters.
It can acquire the DC voltage and current ripple parameters of charging piles, enabling testing for the verification of DC power quality.
Wireless Wi‑Fi and RS485 communication enable connectivity with a mobile app, supporting automated calibration and load control functions.
The device can be powered by AC 220 V/50 Hz or by a built-in battery, with the battery‑powered operation lasting at least 8 hours.
Product Specifications
| Project | Parameter |
| Model number | DC Charging Pile Electrical Energy Metering Verification Device CPMT-1800 |
| Voltage measurement range | DC 0 V to 1500 V |
| Voltage measurement accuracy | ±0.05%RD (30V ≤ U ≤ 1500V) |
| Current measurement range | DC0A~600A |
| Current measurement accuracy | ±0.05%RD (5A ≤ I ≤ 600A) |
| Accuracy of electrical energy measurement | ±0.05%RD (30V ≤ U ≤ 1500V, 5A ≤ I ≤ 600A) |
| Range of settings for the electrical pulse output constant | 1 to 2,000,000,000 |
| Electrical pulse output frequency range | 0.2 Hz~160 kHz |
| Verification cycle setting range | 1~999,999,999 |
| Maximum input frequency of electrical pulses | 50kHz |
| Ripple Measurement Accuracy / Bandwidth | ±0.05% RG, bandwidth ≤ 1 kHz |
| GPS time synchronization accuracy | ≤1us |
| Clock accuracy | ≤0.2 ppm |
| Equivalent resistance value of R4 | 1000 Ω, <0.2% FS |
| Temperature measurement range / Accuracy / Resolution | Range: -40 to 125°C; Accuracy: ≤±0.3°C; Resolution: 0.1°C |
| Humidity measurement range / Accuracy / Resolution | Range: 0–100% RH; Accuracy: ±4% RH; Resolution: 1% RH |
| Atmospheric pressure range / Relative accuracy / Absolute accuracy | Range: 300–1100 hPa (altitude: −500 to +9,000 m); Relative accuracy: ±0.24 hPa (±2 m); Absolute accuracy: ±2 hPa |
Online Inquiry