BDCT Series Battery Pack Constant-Current Discharge Tester
Market price:
Keywords:
BDCT Series Battery Pack Constant-Current Discharge Tester
Product Description
BDCT emphasizes practical applications.
1. Engineering acceptance of newly introduced batteries.
2. DC power supply simulation testing.
3. Routine maintenance testing of batteries. In accordance with the maintenance procedures, conduct periodic verification discharge tests and deep‑discharge tests on batteries that are already in service.
4. The capacity of the battery pack is measured with 100% accuracy through discharge.
5. Replace traditional manual testing methods that are inaccurate and unsafe, ensuring the safety of batteries, communication equipment rooms, and personnel.
BDCT Product Features
1. Equipped with an extra-large touchscreen, allowing direct tap-and-click operations on the screen.
2. Adjustable constant-current discharge setting (stepless): continuously adjustable from 1 to 300 A (select the appropriate model based on requirements).
3. The battery pack’s discharge termination voltage can be set: continuously adjustable, with input via a digital panel.
4. The instrument features parallel‑unit expansion capability, allowing multiple units to be connected in parallel for discharge, thereby accommodating high‑current discharge applications. The start-up and shutdown of the parallel‑connected loads during the discharge process are controlled by the master unit.
5. Connects to a PC and operates in the Windows environment, offering ease of use while simultaneously displaying the trend graphs from both the Battery Pack Constant-Current Discharge Capacity Tester (BDCT) and the Battery Pack Inspection Instrument (BCSU).
6. Equipped with RS232, RS485, and USB data export interfaces.
7. Equipped with reverse‑polarity protection for the positive and negative cables, preventing short circuits caused by incorrect polarity connections.
8. Equipped with data analysis and printing software, it analyzes and prints discharge curves and discharge capacity, and automatically generates test reports.
Technical Specifications of the 6–60 V Discharge Tester
| Characteristics | BDCT-5010 | BDCT-5015 | BDCT-5020 | BDCT-5030 |
|---|---|---|---|---|
| Scope of Application | 24V/48V system | 24V/48V system | 24V/48V system | 24V/48V system |
| Application Industries | Specifically designed for the routine maintenance and testing of communication‑power battery packs. | Same as above | Same as above | Same as above |
| Discharge time | 0–99 hours 59 minutes | 0–99 hours 59 minutes | 0–99 hours 59 minutes | 0–99 hours 59 minutes |
| Maximum discharge power | 6KW | 9KW | 12KW | 18KW |
| Discharge voltage range | DC 18-56V | DC 18-56V | DC 18-56V | DC 18-56V |
| Maximum charging current | 100A | 150A | 200A | 300A |
| Display mode | Touchscreen operation, backlit LCD | Same as above | Same as above | Same as above |
| Protective device | Automatically disconnects the DC input to prevent overcurrent and short circuits. | Same as above | Same as above | Same as above |
| Cooling method | Forced-air cooling type | Same as above | Same as above | Same as above |
Technical Specification Table for 110V/220V (90–300V) Power Supply
| Characteristics | BDCT-2203 | BDCT-2205 | BDCT-2210 | BDCT-2220 | BDCT-2230 | Explanation |
|---|---|---|---|---|---|---|
| Product model | BDCT-2203 | BDCT-2205 | BDCT-2210 | BDCT-2220 | BDCT-2230 | — |
| Discharge current | 0~30A | 0~50A | 0~100A | 0~200A | 0~300A | Resolution: 0.1 A, Accuracy: 1 A |
| Total discharge voltage | 96~270V | 96~270V | 96~270V | 96~270V | 96~270V | Resolution: 10 mV, Accuracy: 0.1 V |
| Discharge cell voltage | 0~16V | 0~16V | 0~16V | 0~16V | 0~16V | Resolution: 1 mV, Accuracy: 10 mV |
| Discharge time | 0~99 hours 59 minutes | Same as above | Same as above | Same as above | Same as above | — |
| Maximum discharge power | 8KW | 14KW | 27KW | 56KW | 84KW | — |
| Cooling method | Forced-air cooling type | Same as above | Same as above | Same as above | Same as above | — |
| Discharge load | Alloy resistor | Same as above | Same as above | Same as above | Same as above | High performance, excellent security |
| Power supply | AC / 220V | Same as above | Same as above | Same as above | Same as above | — |
| Handling method | Double-handled design | Same as above | Same as above | Same as above | Same as above | — |
| Applicable occasions | Portable, mobile, and designed to meet the daily maintenance needs of storage batteries. | Same as above | Same as above | Same as above | Same as above | Various types of power plants and substations |
Technical Specification Sheet for UPS Battery Packs: 380V/600V (100–600V)
| Characteristics | BDCT-5000 | BDCT-5100 | BDCT-5150 | BDCT-6500 |
|---|---|---|---|---|
| Scope of Application | 24V/48V system | 24V/48V system | 24V/48V system | 24V/48V system |
| Application Industries | Specifically designed for the routine maintenance and testing of communication‑power battery packs. | Same as above | Same as above | Same as above |
| Discharge time | 0 hours 59 minutes | 0 hours 59 minutes | 0 hours 59 minutes | 0 hours 59 minutes |
| Maximum discharge power | 28KW | 70KW | 100KW | 300KW |
| Discharge voltage range | DC 300-600V | DC 300-600V | DC 300-600V | DC 300-600V |
| Maximum charging current | 30A | 100A | 150A | 500A |
| Display mode | Backlight, LCD | Same as above | Same as above | Same as above |
| Protective device | Automatically disconnects the DC input to prevent overcurrent and short circuits. | Same as above | Same as above | Same as above |
| Cooling method | Forced-air cooling | Same as above | Same as above | Same as above |
| Environment | -10℃~50℃ 5%~90% RH | Same as above | Same as above | Same as above |
| Display and Print Items | Dynamic display and printing of set and measured parameters, including discharge voltage, discharge current, discharge time, and discharge capacity. | Same as above | Same as above | Same as above |
Online Inquiry