DCLT Series Battery Pack Charge-Discharge Tester
Market price:
Keywords:
DCLT Series Battery Pack Charge-Discharge Tester
Product Description
The Qunling DCLT series battery charge‑discharge tester offers functions such as single‑cell testing, capacity assessment, charge‑discharge cycling, and full‑pack activation. It supports constant‑current and constant‑power modes, intelligent charging, and smart management of test data, providing an integrated solution for battery diagnostics and routine maintenance. Featuring proprietary online capacity‑analysis technology, it enables users to quickly identify lagging cells—tasks that once took ten hours can now be completed in just ten minutes—significantly reducing maintenance effort while enhancing the safety of battery‑maintenance operations.
DCLT = Constant-current discharge of the battery pack + individual cell voltage monitoring + rapid state-of-charge estimation + intelligent charging of the battery pack
Main Features
1. Integrates discharging, charging, and cyclic charge–discharge (activation) into a single unit, enabling a single device to handle all testing and maintenance tasks for battery‑pack maintenance personnel.
2. Meets the requirements for battery‑pack acceptance testing and deep‑discharge tests, capable of sustaining ten hours of continuous discharge and accurately determining the battery’s capacity.
3. Online real-time acquisition and monitoring of the voltage of each individual battery cell, enabling effective assessment of voltage balance among the cells.
4. Multiple discharge modes are supported, including constant current, constant power, and constant resistance, enabling simulation of various real-world load conditions to comprehensively evaluate battery pack performance.
5. Intelligent Cyclic Charge–Discharge: Supports configuring multi-cycle charge–discharge tests, with intelligent settings for prioritizing charging or discharging, dwell time, and automatic transition from equalization to float charging, effectively activating battery chemistry and increasing the battery pack’s capacity.
6. Single-cell voltage acquisition: During charging and discharging, the voltage of each individual cell is collected in real time via wireless, wired, or CAN interfaces, enabling rapid and accurate state-of-charge estimation while protecting the battery from damage due to over‑discharge or over‑charge.
7. Equipped with rapid capacity analysis capabilities, it performs online assessment of the capacity (Ah) of each individual cell, enabling quick identification of lagging cells. It also estimates the remaining battery capacity and evaluates battery health.
8. Activation Function: The instrument supports configuring multi-cycle charge–discharge tests, with intelligent settings for prioritizing charging or discharging, setting rest periods, and automatically switching between equalization charging and float charging. This effectively activates battery activity and enhances the overall capacity of the battery pack.
9. Real-time online monitoring and display of all test data: current, battery pack voltage, individual cell voltage, internal resistance, discharge time, and capacity; at the conclusion of the verification discharge test, it can rapidly determine the remaining capacity of each individual cell.
10. Equipped with multiple intelligent interfaces: RS485, RS232, RJ45, CAN, and other data interfaces, supporting communication with lithium‑battery BMSs, host computers, and other smart devices.
Technical Specifications: 6–60 V
| Product model | DCLT-4805 | DCLT-4810 | DCLT-4820 | DCLT-4830 | Note |
|---|---|---|---|---|---|
| Discharge current | 0~50A | 0~100A | 0~200A | 0~300A | Resolution: 0.1 A, Accuracy: 1 A |
| Charging current | 0~50A | 0~100A | 0~200A | 0~300A | Resolution: 0.1 A, Accuracy: 1 A |
| Total discharge voltage | — | 10~56V | — | — | Resolution: 10 mV, Accuracy: 0.1 V |
| Total charging voltage | — | 2~60V | — | — | Resolution: 10 mV, Accuracy: 0.1 V |
| Single-cell charge/discharge voltage | — | 0.500V~16.00V | — | — | Resolution: 1 mV, Accuracy: 10 mV |
| Charge and discharge time | — | 0~99 hours 59 minutes | — | — | — |
| Number of single cells | — | Verses 1–24 | — | — | The individual cell voltage monitoring function can be disabled. |
| Cooling method | — | Forced-air cooling type | — | — | — |
| Discharge load | — | Alloy resistor | — | — | High performance, excellent security |
| Power supply | — | AC 220 V/50 Hz for power-on and discharge testing, or AC 380 V/50 Hz for charging testing. | — | — | — |
Technical Specification Table for 110V/220V (90–300V) Power Supply
| Product model | DCLT-2203 | DCLT-2205 | DCLT-2210 | DCLT-1105 | DCLT-1110 | Note |
|---|---|---|---|---|---|---|
| Charge and discharge current | 0~30A | 0~50A | 0~100A | 0~50A | 0~100A | Resolution: 0.1 A, Accuracy: 1 A |
| Total charging voltage | 0~60V | — | — | — | — | Resolution: 0.1 A, Accuracy: 1 A* |
| Total discharge voltage | 96~270V | 96~150V | 96~150V | 96~150V | 96~150V | Resolution: 10 mV, Accuracy: 0.1 V |
| Total charging voltage output | 96~270V continuously adjustable | — | — | — | — | Resolution: 10 mV, Accuracy: 0.1 V |
| Single-cell charge/discharge voltage | 0.500V~16.00V | Same as above | Same as above | Same as above | Same as above | Resolution: 1 mV, Accuracy: 10 mV |
| Number of monitored batteries | 1 group of 108 cells, 2V single cell; a 12V single cell can detect 18 cells. | — | — | 1 group of 54 cells, 2V single cell; a 12V single cell can detect 10 cells. | — | The individual cell voltage monitoring function can be disabled. |
| Charge and discharge time | 0~99 hours 59 minutes | Same as above | Same as above | Same as above | Same as above | — |
| Cooling method | Forced air cooling | Same as above | Same as above | Same as above | Same as above | High performance, excellent security |
| Discharge load | Alloy resistive type | Same as above | Same as above | Same as above | Same as above | — |
| Power supply | AC 220 V/50 Hz for power-on and discharge testing; AC 380 V/50 Hz for charging testing. | — | — | — | — | — |
Technical Specification Sheet for UPS Battery Packs: 380V/600V (100–600V)
| Product model | DCLT3810 | DCLT3830 | DCLT3850 | Note |
|---|---|---|---|---|
| Discharge current | 0~10A | 0~30A | 0~50A | Resolution: 0.1 A, Accuracy: 1 A |
| Charging current | 0~10A | 0~30A | 0~50A | Resolution: 0.1 A, Accuracy: 1 A |
| Total discharge voltage | — | 300~600V | — | Resolution: 10 mV, Accuracy: 0.1 V |
| Single-cell charge/discharge voltage | — | 0.500V~16.00V | — | Resolution: 1 mV, Accuracy: 10 mV |
| Charge and discharge time | — | 0~99 hours 59 minutes | — | — |
| Number of single cells | — | 1~36 | — | The individual cell voltage monitoring function can be disabled. |
| Cooling method | — | Forced-air cooling type | — | — |
| Discharge load | — | Alloy resistor | — | High performance, excellent security |
| Power supply | — | AC 220 V/50 Hz for power-on and discharge testing; AC 380 V/50 Hz for charging testing. | — | — |