QLKW Series Regenerative Battery Pack Charge-Discharge Equipment
Market price:
Keywords:
QLKW Series Regenerative Battery Pack Charge-Discharge Equipment
Product Description
The QLKW series regenerative charge‑discharge equipment is designed for the charge‑discharge maintenance of complete high‑voltage battery systems in large warehouses or vehicle manufacturers. It supports lithium‑ion battery packs across a wide voltage range and with high power ratings, enabling centralized maintenance and servicing. Featuring a regenerative discharge mode, the system generates no additional heat on site, ensuring efficient, energy‑saving, and safe testing.
Main applications
Maintenance and care of lithium‑ion battery packs during after-sales service, at 4S dealerships, and in storage and transportation.
Product Features
Energy Feedback: The entire system features bidirectional energy flow and automatically regulates energy direction. During charging and discharging maintenance, the battery pack feeds energy back to the three-phase grid, with a DC bus efficiency of ≥93%, significantly reducing electricity costs and air-conditioning expenses associated with heat‑intensive maintenance.
High‑power isolation transformer; the entire system is isolated from the grid, with fast output current response and no overshoot, ensuring reliable and stable operation.
The DC/AC module employs space vector modulation and digital control, resulting in high voltage utilization and reduced current harmonic distortion.
The DC/DC module employs advanced PID control technology and multiple protection mechanisms to ensure stable equipment operation.
Capable of communicating with external tooling, receiving external information, and executing control commands.
CCCV Charging: The charging process is free from any voltage or current surges, effectively preventing thermal hotspots caused by peak currents that could lead to tab powder shedding or micro‑short circuits, thereby avoiding islanding effects or over‑charging that might trigger PCB protection and secondary protection mechanisms.
It employs high-precision, high‑dynamic‑range ADC/DAC modules, delivering excellent voltage‑sampling accuracy and superior long-term stability.
DCIR DC Internal Resistance Testing: Real-time measurement of load impedance within milliseconds during battery charging with a load or sudden discharge, enabling identification of batteries with unstable DCIR.
Voltage clamping: During charging, if the battery protection is triggered or a device fault occurs, the voltage can be clamped at the set value to prevent damage to the protection board.
ECD & EVD Protection: Prevents batteries that fail to meet specified criteria from triggering automatic protection and prematurely terminating charging or discharging.
Product Specifications
Model number | QLKW‑120K | QLKW‑200K | QLKW‑500K | QLKW‑500K‑2CH Multi-channel |
Current range | 0~160A | 0~250A | 0~500A | 0~500A |
Power | 120kW | 200kW | 500kW | 500kW |
Voltage range | 200~750V (customizable 200~1000V) | |||
AC input interface | Input: Three-phase four-wire, AC 380 V ±10%, 50 Hz | |||
THD | ≤3% | |||
Power factor | >0.99 (rated power) | |||
Charging efficiency | 94% (rated power) | |||
Feedback efficiency | 93% (rated power) | |||
Voltage accuracy | ±0.5% of F.S ±0.1% of F.D | |||
Current accuracy | ±1% of FS ±0.5% of F.D | |||
Voltage and current detection sampling | Four-wire connection | |||
Online Inquiry