DCLT-1010TL 1–100 V Series Integrated Lithium Battery Charge/Discharge Unit
Market price:
Keywords:
DCLT-1010TL 1–100 V Series Integrated Lithium Battery Charge/Discharge Unit
Product Description
The lithium‑battery charge‑discharge tester employs intelligent charging and discharging technology and features multiple built-in test and maintenance modes, making it suitable for discharge, charge, and cycle‑life testing of new‑energy batteries. During charging and discharging, it monitors cell voltage to prevent over‑discharge and over‑charge.
Product Features
Multi‑function in one device: Designed with a wide voltage range, it is suitable for discharge, charge, and activation testing of modules and battery packs across various voltage levels.
Multiple discharge modes: Supports constant-current and constant-power discharge modes to meet diverse application requirements.
High-efficiency charging mode: ensures the battery pack is fully charged, significantly improving charging efficiency.
Battery Pack Activation: Freely configure charging and discharging parameters and the number of activation cycles to effectively increase battery capacity.
Communication Interface: Employs CAN and RS485 protocols to acquire cell voltages, supporting remote communication applications.
Data Acquisition: Capable of collecting data such as the maximum and minimum voltages and temperatures of individual battery strings, with the acquired data displayed intuitively on the screen in the form of bar charts, reports, and trend curves.
Product Specifications
Model number | DCLT‑1010TL | DCLT‑10030TL‑CN |
Charge and discharge voltage | DC 2~100V | 1–4 channels DC 2–100 V |
Discharge current | 0~100A, 10kW Max | 0~50A, 5kW Max |
Charging current | 0~100A, 10kW Max | 0~50A, 5kW Max |
Voltage Accuracy and Resolution | Accuracy: 0.5% FS; full‑range resolution: 0.1 V; single‑channel resolution: 0.001 V. | Accuracy: 0.5% FS; full‑range resolution: 0.1 V; single‑channel resolution: 0.001 V. |
Current accuracy | 1%FS | 1%FS |
Supply voltage | 110/220V AC | 110/220V AC |
Work mode | Constant-current discharge, constant-power discharge, constant-current charging, constant-voltage charging, activation testing | Constant-current discharge, constant-power discharge, constant-current charging, constant-voltage charging, activation testing |
Cell voltage acquisition | BMS communication (RS485, CAN), physical clip cable | BMS communication (RS485, CAN), physical clip cable |
Security Protection | Overvoltage, undervoltage, and overcurrent protection; reverse polarity protection; system overtemperature protection; overcharge and overdischarge protection. | Overvoltage, undervoltage, and overcurrent protection; reverse polarity protection; system overtemperature protection; overcharge and overdischarge protection. |
Online Inquiry