DC-2205 New Energy Vehicle Charge/Discharge Tester
Market price:
Keywords:
DC-2205 New Energy Vehicle Charge/Discharge Tester
Product Description
The lithium‑battery discharge unit is designed to meet the demand for rapid discharging of high‑voltage lithium battery packs, with a discharge voltage of up to 800 V. Equipped with a CAN data bus, it can acquire cell‑level data during discharge, making it an ideal solution for battery manufacturers and vehicle OEMs to perform fast discharge during battery pack storage, transportation, repair, and recycling, thereby reducing risks associated with battery handling and logistics.
It meets the requirements for battery disposal stipulated in the “Guidelines for the Construction and Operation of New Energy Vehicle Power Battery Recycling Service Outlets” and the “Operational Mechanism of the ‘Co‑construction and Co‑sharing’ Power Battery Recycling Service System.”
Main applications
Battery manufacturers, automakers’ battery‑pack storage and transportation, repair and recycling, cell‑level sampling and inspection, and other related processes—battery testing for new‑energy vehicles.
Product Features
Discharge: The maximum discharge voltage can reach 1000 V, meeting the discharge requirements of various high-voltage lithium‑ion battery packs.
Cell data acquisition: Equipped with a CAN bus, it can read cell data during discharge.
Multi‑layer protection: cell over‑discharge, over‑temperature; host over‑temperature, over‑current, current‑control failure; reverse polarity, and other safeguards.
Smart barcode scanner function: Quickly reads the battery pack’s serial number.
Data Printing Function: Test data, quick printing and viewing.
Product Specifications
| Project | DC‑2205 | DC‑10030 |
| Discharge voltage range | 2~200V | 120~1000V |
| Discharge current range | 0.1~50A | 120–200 V: 0–30 A; 200–1000 V: 0–80 A; maximum power rating: 30 kW |
| Maximum discharge power | 10kW | 30kW |
| Discharge operating mode | Constant-current discharge, constant-power discharge | |
| Voltage resolution / accuracy | 0.1 V; ±0.5% FS, maximum range: 800 V | 0.1 V; ±0.5% FS, maximum range: 1000 V |
| Current resolution / accuracy | 0.1 A; ±1% FS, maximum range: 60 A | 0.1 A; ±1% FS, maximum range: 80 A |
| Discharge protection | Over-discharge protection for battery strings and over-temperature protection for battery strings (requires protocol support) | |
| Host Protection | Over-temperature, over-current, and loss-of-control protection with automatic shutdown. | |
| Charging method | Four-stage charging (constant current 1, constant current 2, constant voltage with current limiting, and float charge) can be customized to meet specific requirements. | |
| Work mode | Multiple operating modes are available for flexible selection (three modes: charge-only, discharge-only, and charge–discharge cycling). | |
Online Inquiry